V-PRO® Low Temperature Sterilization Systems enables Customers to enhance their overall performance, reduce inventory, save time and money and ensure a high standard of patient care. V-PRO Low Temperature Sterilization Systems are intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) reusable metal and nonmetal medical devices used in healthcare facilities. The STERIS-developed low pressure and low temperature sterilization cycles are suitable for sterilizing medical devices sensitive to heat and moisture.Systems enables Customers to enhance their overall performance, reduce inventory, save time and money and ensure a high standard of patient care. V-PRO Low Temperature Sterilization Systems are intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) reusable metal and nonmetal medical devices used in healthcare facilities. The STERIS-developed low pressure and low temperature sterilization cycles are suitable for sterilizing medical devices sensitive to heat and moisture.
AMSCO® V-PRO™ maX Low Temperature Sterilizer for heat and moisture sensitive devices
AMSCO® V-PRO™ Max Low Temperature Sterilizer
With outstanding material compatibility and sterilization power, the V-PRO maX sterilizer makes sterile processing departments more productive, consistent and dependable resulting in maximum performance while ensuring a high standard of patient care.
With three processing cycles available, the V-PRO maX sterilizer efficiently sterilizes a variety of instrument types. A new Flexible Cycle enables users to sterilize single and dual channell surgical flexible endoscopes with or without load in 35 minutes. A 28-minute Non Lumen Cycle sterilizes devices such as telescopes, bipolar forceps, cameras, light cables, batteries, and non lumened endoscopes. For sterilization of stainless steel lumened instruments such as resectoscopes, trocars, and cannulas, the V-PRO maX sterilizer offers a 55-minute Lumen Cycle.
The V-PRO maX sterilizes with 59% hydrogen peroxide throughout each cycle versus other sterilizers that concentrate sterilant up to 94%. The lower concentration of hydrogen peroxide reduces the risk of device and instrument damage.
The V-PRO maX sterilizer can quickly process heatstable, heat-sensitive, and moisture-sensitive devices.
Reliable: Minimized aborted cycles, saving time and money and maximizing devices turnaound
Gentle: Optimizing efficacy and reducing dramatically damages to devices thanks to VHP® technology process
Wide compatibility: The VHP® Technology allows for a low sterilant concentration (only 59% Hydrogen Peroxide).the process is adapted for a wide range of moisture / heat sensitive instruments from manufacturers such as Olympus®, daVinci® and STORZ®
V-PRO® 60 LOW TEMPERATURE STERILIZER
V-PRO® 60 LOW TEMPERATURE STERILIZER
The V-PRO 60 Low Temperature Sterilization System is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) reusable metal and nonmetal medical devices used in Healthcare Facilities. Sterilization Cycles are suitable for sterilizing medical devices sensitive to heat and moisture.
The V-PRO 60 Low Temperature Sterilization System is specifically designed to only process goods using vaporized hydrogen peroxide under vacuum conditions. The process is fully automated, is compatible with a broad range of materials and has rapid Sterilization Cycle times. There are no toxic by-products created by the Sterilization Cycle – only water vapor and oxygen are produced.
The V-PRO 60 Low Temperature Sterilization System performs three pre-programmed Sterilization Cycles: the Lumen Cycle, the Non Lumen Cycle and the Flexible Cycle.
Chamber Size: 330 x 711 x 254 mm
MOBILE & COMPACT
Small footprint, Small chamber but large capacity!
The 60L chamber size allows users to process multiple devices per load. The V-PRO® 60 sterilizer is available on a rolling cart, for mobility storage of accessories.
RELIABLE
The low sensitivity to moisture reduces aborted cycles. Low maintenance.
WIDELY COMPATIBLE
Gentle with your devices.
The VHP® Technology allows for a low sterilant concentration (only 59% Hydrogen Peroxide). The process is therefore adapted for a wide range of moisture / heat sensitive instruments from manufacturers such as Olympus®, daVinci® and STORZ®.
We constantly update our long list of instruments validated for sterilization in the V-PRO® 60 sterilizer. The online matrix will help you find your instrument reference.